authorStefan Agner <stefan.agner@toradex.com>2014-03-10 14:01:29 +0100
committerStefan Agner <stefan.agner@toradex.com>2014-03-10 14:22:39 +0100
commit56db5e2dc402ec8dd7ba922ec5ae1b450ed95d43 (patch)
treecd0c50d4e17dedde498d56c1016d5a8978c6e006 /arch
parentd853a0bd57599165e18eea18b0d3abf467331cf0 (diff)
tty: serial: tegra: initialize with lower baudrate
While setup, there is a time the serial port is running on a predefined speed (115200). When data arrived during this phase at a lower baudrate (e.g. 9600), a lot of overrun and break error messages were shown. Due to those messages, the terminal setup never finished, and thus never reached the selected baudrate (e.g. 9600). By choosing a lower baudrate at the startup (9600), a lot less (if any at all) messages are shown and those initialization always succeeds. Another solution would be to disable those messages completely. However, while normal mode its good to have those UART error messages.