summaryrefslogtreecommitdiff
path: root/drivers/net/ixgbe/ixgbe_82598.c
diff options
context:
space:
mode:
authorPeter P Waskiewicz Jr <peter.p.waskiewicz.jr@intel.com>2009-02-06 21:46:54 -0800
committerDavid S. Miller <davem@davemloft.net>2009-02-06 21:46:54 -0800
commit0ecc061d1967e9f2694502079e00d9d6e1e39072 (patch)
tree40a06f43717f97d6dade8fbb55bad15740033799 /drivers/net/ixgbe/ixgbe_82598.c
parent394827913e371b058849349c6fc9d52c59c31a3d (diff)
ixgbe: Update flow control state machine in link setup
The flow control handling is overly complicated and difficult to maintain. This patch cleans up the flow control handling and makes it much more explicit. It also adds 1G flow control autonegotiation, for 1G copper links, 1G KX links, and 1G fiber links. Signed-off-by: Peter P Waskiewicz Jr <peter.p.waskiewicz.jr@intel.com> Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com> Signed-off-by: David S. Miller <davem@davemloft.net>
Diffstat (limited to 'drivers/net/ixgbe/ixgbe_82598.c')
-rw-r--r--drivers/net/ixgbe/ixgbe_82598.c177
1 files changed, 113 insertions, 64 deletions
diff --git a/drivers/net/ixgbe/ixgbe_82598.c b/drivers/net/ixgbe/ixgbe_82598.c
index f726a14d1a73..525bd87fea56 100644
--- a/drivers/net/ixgbe/ixgbe_82598.c
+++ b/drivers/net/ixgbe/ixgbe_82598.c
@@ -255,104 +255,75 @@ static enum ixgbe_media_type ixgbe_get_media_type_82598(struct ixgbe_hw *hw)
}
/**
- * ixgbe_setup_fc_82598 - Configure flow control settings
+ * ixgbe_fc_enable_82598 - Enable flow control
* @hw: pointer to hardware structure
* @packetbuf_num: packet buffer number (0-7)
*
- * Configures the flow control settings based on SW configuration. This
- * function is used for 802.3x flow control configuration only.
+ * Enable flow control according to the current settings.
**/
-static s32 ixgbe_setup_fc_82598(struct ixgbe_hw *hw, s32 packetbuf_num)
+static s32 ixgbe_fc_enable_82598(struct ixgbe_hw *hw, s32 packetbuf_num)
{
- u32 frctl_reg;
+ s32 ret_val = 0;
+ u32 fctrl_reg;
u32 rmcs_reg;
+ u32 reg;
- if (packetbuf_num < 0 || packetbuf_num > 7) {
- hw_dbg(hw, "Invalid packet buffer number [%d], expected range is"
- " 0-7\n", packetbuf_num);
- }
-
- frctl_reg = IXGBE_READ_REG(hw, IXGBE_FCTRL);
- frctl_reg &= ~(IXGBE_FCTRL_RFCE | IXGBE_FCTRL_RPFCE);
+ fctrl_reg = IXGBE_READ_REG(hw, IXGBE_FCTRL);
+ fctrl_reg &= ~(IXGBE_FCTRL_RFCE | IXGBE_FCTRL_RPFCE);
rmcs_reg = IXGBE_READ_REG(hw, IXGBE_RMCS);
rmcs_reg &= ~(IXGBE_RMCS_TFCE_PRIORITY | IXGBE_RMCS_TFCE_802_3X);
/*
- * 10 gig parts do not have a word in the EEPROM to determine the
- * default flow control setting, so we explicitly set it to full.
- */
- if (hw->fc.type == ixgbe_fc_default)
- hw->fc.type = ixgbe_fc_full;
-
- /*
- * We want to save off the original Flow Control configuration just in
- * case we get disconnected and then reconnected into a different hub
- * or switch with different Flow Control capabilities.
- */
- hw->fc.original_type = hw->fc.type;
-
- /*
- * The possible values of the "flow_control" parameter are:
+ * The possible values of fc.current_mode are:
* 0: Flow control is completely disabled
- * 1: Rx flow control is enabled (we can receive pause frames but not
- * send pause frames).
- * 2: Tx flow control is enabled (we can send pause frames but we do not
- * support receiving pause frames)
+ * 1: Rx flow control is enabled (we can receive pause frames,
+ * but not send pause frames).
+ * 2: Tx flow control is enabled (we can send pause frames but
+ * we do not support receiving pause frames).
* 3: Both Rx and Tx flow control (symmetric) are enabled.
* other: Invalid.
*/
- switch (hw->fc.type) {
+ switch (hw->fc.current_mode) {
case ixgbe_fc_none:
+ /* Flow control completely disabled by software override. */
break;
case ixgbe_fc_rx_pause:
/*
- * Rx Flow control is enabled,
- * and Tx Flow control is disabled.
+ * Rx Flow control is enabled and Tx Flow control is
+ * disabled by software override. Since there really
+ * isn't a way to advertise that we are capable of RX
+ * Pause ONLY, we will advertise that we support both
+ * symmetric and asymmetric Rx PAUSE. Later, we will
+ * disable the adapter's ability to send PAUSE frames.
*/
- frctl_reg |= IXGBE_FCTRL_RFCE;
+ fctrl_reg |= IXGBE_FCTRL_RFCE;
break;
case ixgbe_fc_tx_pause:
/*
- * Tx Flow control is enabled, and Rx Flow control is disabled,
- * by a software over-ride.
+ * Tx Flow control is enabled, and Rx Flow control is
+ * disabled by software override.
*/
rmcs_reg |= IXGBE_RMCS_TFCE_802_3X;
break;
case ixgbe_fc_full:
- /*
- * Flow control (both Rx and Tx) is enabled by a software
- * over-ride.
- */
- frctl_reg |= IXGBE_FCTRL_RFCE;
+ /* Flow control (both Rx and Tx) is enabled by SW override. */
+ fctrl_reg |= IXGBE_FCTRL_RFCE;
rmcs_reg |= IXGBE_RMCS_TFCE_802_3X;
break;
default:
- /* We should never get here. The value should be 0-3. */
hw_dbg(hw, "Flow control param set incorrectly\n");
+ ret_val = -IXGBE_ERR_CONFIG;
+ goto out;
break;
}
/* Enable 802.3x based flow control settings. */
- IXGBE_WRITE_REG(hw, IXGBE_FCTRL, frctl_reg);
+ IXGBE_WRITE_REG(hw, IXGBE_FCTRL, fctrl_reg);
IXGBE_WRITE_REG(hw, IXGBE_RMCS, rmcs_reg);
- /*
- * Check for invalid software configuration, zeros are completely
- * invalid for all parameters used past this point, and if we enable
- * flow control with zero water marks, we blast flow control packets.
- */
- if (!hw->fc.low_water || !hw->fc.high_water || !hw->fc.pause_time) {
- hw_dbg(hw, "Flow control structure initialized incorrectly\n");
- return IXGBE_ERR_INVALID_LINK_SETTINGS;
- }
-
- /*
- * We need to set up the Receive Threshold high and low water
- * marks as well as (optionally) enabling the transmission of
- * XON frames.
- */
- if (hw->fc.type & ixgbe_fc_tx_pause) {
+ /* Set up and enable Rx high/low water mark thresholds, enable XON. */
+ if (hw->fc.current_mode & ixgbe_fc_tx_pause) {
if (hw->fc.send_xon) {
IXGBE_WRITE_REG(hw, IXGBE_FCRTL(packetbuf_num),
(hw->fc.low_water | IXGBE_FCRTL_XONE));
@@ -360,14 +331,93 @@ static s32 ixgbe_setup_fc_82598(struct ixgbe_hw *hw, s32 packetbuf_num)
IXGBE_WRITE_REG(hw, IXGBE_FCRTL(packetbuf_num),
hw->fc.low_water);
}
+
IXGBE_WRITE_REG(hw, IXGBE_FCRTH(packetbuf_num),
- (hw->fc.high_water)|IXGBE_FCRTH_FCEN);
+ (hw->fc.high_water | IXGBE_FCRTH_FCEN));
}
- IXGBE_WRITE_REG(hw, IXGBE_FCTTV(0), hw->fc.pause_time);
+ /* Configure pause time (2 TCs per register) */
+ reg = IXGBE_READ_REG(hw, IXGBE_FCTTV(packetbuf_num));
+ if ((packetbuf_num & 1) == 0)
+ reg = (reg & 0xFFFF0000) | hw->fc.pause_time;
+ else
+ reg = (reg & 0x0000FFFF) | (hw->fc.pause_time << 16);
+ IXGBE_WRITE_REG(hw, IXGBE_FCTTV(packetbuf_num / 2), reg);
+
IXGBE_WRITE_REG(hw, IXGBE_FCRTV, (hw->fc.pause_time >> 1));
- return 0;
+out:
+ return ret_val;
+}
+
+/**
+ * ixgbe_setup_fc_82598 - Configure flow control settings
+ * @hw: pointer to hardware structure
+ * @packetbuf_num: packet buffer number (0-7)
+ *
+ * Configures the flow control settings based on SW configuration. This
+ * function is used for 802.3x flow control configuration only.
+ **/
+static s32 ixgbe_setup_fc_82598(struct ixgbe_hw *hw, s32 packetbuf_num)
+{
+ s32 ret_val = 0;
+ ixgbe_link_speed speed;
+ bool link_up;
+
+ /* Validate the packetbuf configuration */
+ if (packetbuf_num < 0 || packetbuf_num > 7) {
+ hw_dbg(hw, "Invalid packet buffer number [%d], expected range is"
+ " 0-7\n", packetbuf_num);
+ ret_val = IXGBE_ERR_INVALID_LINK_SETTINGS;
+ goto out;
+ }
+
+ /*
+ * Validate the water mark configuration. Zero water marks are invalid
+ * because it causes the controller to just blast out fc packets.
+ */
+ if (!hw->fc.low_water || !hw->fc.high_water || !hw->fc.pause_time) {
+ hw_dbg(hw, "Invalid water mark configuration\n");
+ ret_val = IXGBE_ERR_INVALID_LINK_SETTINGS;
+ goto out;
+ }
+
+ /*
+ * Validate the requested mode. Strict IEEE mode does not allow
+ * ixgbe_fc_rx_pause because it will cause testing anomalies.
+ */
+ if (hw->fc.strict_ieee && hw->fc.requested_mode == ixgbe_fc_rx_pause) {
+ hw_dbg(hw, "ixgbe_fc_rx_pause not valid in strict IEEE mode\n");
+ ret_val = IXGBE_ERR_INVALID_LINK_SETTINGS;
+ goto out;
+ }
+
+ /*
+ * 10gig parts do not have a word in the EEPROM to determine the
+ * default flow control setting, so we explicitly set it to full.
+ */
+ if (hw->fc.requested_mode == ixgbe_fc_default)
+ hw->fc.requested_mode = ixgbe_fc_full;
+
+ /*
+ * Save off the requested flow control mode for use later. Depending
+ * on the link partner's capabilities, we may or may not use this mode.
+ */
+
+ hw->fc.current_mode = hw->fc.requested_mode;
+
+ /* Decide whether to use autoneg or not. */
+ hw->mac.ops.check_link(hw, &speed, &link_up, false);
+ if (hw->phy.multispeed_fiber && (speed == IXGBE_LINK_SPEED_1GB_FULL))
+ ret_val = ixgbe_fc_autoneg(hw);
+
+ if (ret_val)
+ goto out;
+
+ ret_val = ixgbe_fc_enable_82598(hw, packetbuf_num);
+
+out:
+ return ret_val;
}
/**
@@ -414,7 +464,6 @@ static s32 ixgbe_setup_mac_link_82598(struct ixgbe_hw *hw)
* case we get disconnected and then reconnected into a different hub
* or switch with different Flow Control capabilities.
*/
- hw->fc.original_type = hw->fc.type;
ixgbe_setup_fc_82598(hw, 0);
/* Add delay to filter out noises during initial link setup */