summaryrefslogtreecommitdiff
diff options
context:
space:
mode:
authorwdenk <wdenk>2005-02-07 19:44:17 +0000
committerwdenk <wdenk>2005-02-07 19:44:17 +0000
commite799d3755e83c70bf8c92977190d1777b390a8de (patch)
treeedec52df4a91e0130485d4c840de1a261177f758
parent2f916943c9b85d628c67c8ac98e604f2bcbc21e4 (diff)
Fix cirrus voltage detection (for CPC45)LABEL_2005_02_07_2045
-rw-r--r--CHANGELOG2
-rw-r--r--drivers/i82365.c69
2 files changed, 33 insertions, 38 deletions
diff --git a/CHANGELOG b/CHANGELOG
index dc1423eb15..720ecaaedf 100644
--- a/CHANGELOG
+++ b/CHANGELOG
@@ -2,6 +2,8 @@
Changes for U-Boot 1.1.3:
======================================================================
+* Fix cirrus voltage detection (for CPC45)
+
* Fix byteorder problem in usbboot and scsiboot commands.
* Patch by Cajus Hahn, 04 Feb 2005:
diff --git a/drivers/i82365.c b/drivers/i82365.c
index e20fd33e89..a40fcf41c9 100644
--- a/drivers/i82365.c
+++ b/drivers/i82365.c
@@ -1,5 +1,5 @@
/*
- * (C) Copyright 2003-2004
+ * (C) Copyright 2003-2005
* Wolfgang Denk, DENX Software Engineering, wd@denx.de.
*
* See file CREDITS for list of people who contributed to this
@@ -443,31 +443,6 @@ static int cb_set_power (socket_info_t * s, socket_state_t * state)
#ifdef CONFIG_CPC45
- if ((state->Vcc == 0) && (state->Vpp == 0)) {
- u_char power, vcc, vpp;
-
- power = i365_get (s, I365_POWER);
- state->flags |= (power & I365_PWR_AUTO) ? SS_PWR_AUTO : 0;
- state->flags |= (power & I365_PWR_OUT) ? SS_OUTPUT_ENA : 0;
- vcc = power & I365_VCC_MASK;
- vpp = power & I365_VPP1_MASK;
- state->Vcc = state->Vpp = 0;
- if (i365_get (s, PD67_MISC_CTL_1) & PD67_MC1_VCC_3V) {
- if (power & I365_VCC_5V)
- state->Vcc = 33;
- if (vpp == I365_VPP1_5V)
- state->Vpp = 33;
- } else {
- if (power & I365_VCC_5V)
- state->Vcc = 50;
- if (vpp == I365_VPP1_5V)
- state->Vpp = 50;
- }
- if (power == I365_VPP1_12V)
- state->Vpp = 120;
- printf ("POWER Vcc:%d Vpp: %d\n", state->Vcc, state->Vpp);
- }
-
reg = I365_PWR_NORESET;
if (state->flags & SS_PWR_AUTO)
reg |= I365_PWR_AUTO;
@@ -497,8 +472,11 @@ static int cb_set_power (socket_info_t * s, socket_state_t * state)
return -1;
}
}
- if (reg != i365_get (s, I365_POWER))
+
+ if (reg != i365_get (s, I365_POWER)) {
+ reg = (I365_PWR_OUT | I365_PWR_NORESET | I365_VCC_5V | I365_VPP1_5V);
i365_set (s, I365_POWER, reg);
+ }
#else /* ! CONFIG_CPC45 */
@@ -579,6 +557,12 @@ static void set_bridge_opts (socket_info_t * s)
}
/*====================================================================*/
+#define PD67_EXT_INDEX 0x2e /* Extension index */
+#define PD67_EXT_DATA 0x2f /* Extension data */
+#define PD67_EXD_VS1(s) (0x01 << ((s)<<1))
+
+#define pd67_ext_get(s, r) \
+ (i365_set(s, PD67_EXT_INDEX, r), i365_get(s, PD67_EXT_DATA))
static int i365_get_status (socket_info_t * s, u_int * value)
{
@@ -586,6 +570,7 @@ static int i365_get_status (socket_info_t * s, u_int * value)
#ifdef CONFIG_CPC45
u_char val;
u_char power, vcc, vpp;
+ u_int powerstate;
#endif
status = i365_get (s, I365_IDENT);
@@ -620,24 +605,32 @@ static int i365_get_status (socket_info_t * s, u_int * value)
return -1;
}
- i365_bset (s, I365_POWER, I365_VCC_5V);
power = i365_get (s, I365_POWER);
state.flags |= (power & I365_PWR_AUTO) ? SS_PWR_AUTO : 0;
state.flags |= (power & I365_PWR_OUT) ? SS_OUTPUT_ENA : 0;
vcc = power & I365_VCC_MASK;
vpp = power & I365_VPP1_MASK;
state.Vcc = state.Vpp = 0;
- if (i365_get (s, PD67_MISC_CTL_1) & PD67_MC1_VCC_3V) {
- if (power & I365_VCC_5V)
- state.Vcc = 33;
- if (vpp == I365_VPP1_5V)
- state.Vpp = 33;
- } else {
- if (power & I365_VCC_5V)
- state.Vcc = 50;
- if (vpp == I365_VPP1_5V)
- state.Vpp = 50;
+ if((vcc== 0) || (vpp == 0)) {
+ /*
+ * On the Cirrus we get the info which card voltage
+ * we have in EXTERN DATA and write it to MISC_CTL1
+ */
+ powerstate = pd67_ext_get(s, PD67_EXTERN_DATA);
+ if (powerstate & PD67_EXD_VS1(0)) {
+ /* 5V Card */
+ i365_bclr (s, PD67_MISC_CTL_1, PD67_MC1_VCC_3V);
+ } else {
+ /* 3.3V Card */
+ i365_bset (s, PD67_MISC_CTL_1, PD67_MC1_VCC_3V);
+ }
+ i365_set (s, I365_POWER, (I365_PWR_OUT | I365_PWR_NORESET | I365_VCC_5V | I365_VPP1_5V));
+ power = i365_get (s, I365_POWER);
}
+ if (power & I365_VCC_5V) {
+ state.Vcc = (i365_get(s, PD67_MISC_CTL_1) & PD67_MC1_VCC_3V) ? 33 : 50;
+ }
+
if (power == I365_VPP1_12V)
state.Vpp = 120;