authorStefan Agner <stefan@agner.ch>2018-07-05 14:18:19 +0200
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>2018-09-26 08:36:38 +0200
commit7cca66510abdeca27e78016af71c0a48d156a05b (patch)
tree82b6c24fea661f4e07db33199c6209db311ca8c0
parent330b72fc294d0f03ca70a01fda9890b0c9539db9 (diff)
mmc: sdhci: do not try to use 3.3V signaling if not supported
[ Upstream commit 1b5190c2e74c47ebe4bcecf7a072358ad9f1feaa ] For eMMC devices it is valid to only support 1.8V signaling. When vqmmc is set to a fixed 1.8V regulator the stack tries to set 3.3V initially and prints the following warning: mmc1: Switching to 3.3V signalling voltage failed Clear the MMC_SIGNAL_VOLTAGE_330 flag in case 3.3V is signaling is not available. This prevents the stack from even trying to use 3.3V signaling and avoids the above warning. Signed-off-by: Stefan Agner <stefan@agner.ch> Signed-off-by: Ulf Hansson <ulf.hansson@linaro.org> Signed-off-by: Sasha Levin <alexander.levin@microsoft.com> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
-rw-r--r--drivers/mmc/host/sdhci.c9
1 files changed, 8 insertions, 1 deletions
diff --git a/drivers/mmc/host/sdhci.c b/drivers/mmc/host/sdhci.c
index 44ea9d88651f..6bf58d27b6fc 100644
--- a/drivers/mmc/host/sdhci.c
+++ b/drivers/mmc/host/sdhci.c
@@ -3328,14 +3328,21 @@ int sdhci_setup_host(struct sdhci_host *host)
mmc_gpio_get_cd(host->mmc) < 0)
mmc->caps |= MMC_CAP_NEEDS_POLL;
- /* If vqmmc regulator and no 1.8V signalling, then there's no UHS */
if (!IS_ERR(mmc->supply.vqmmc)) {
ret = regulator_enable(mmc->supply.vqmmc);
+
+ /* If vqmmc provides no 1.8V signalling, then there's no UHS */
if (!regulator_is_supported_voltage(mmc->supply.vqmmc, 1700000,
1950000))
host->caps1 &= ~(SDHCI_SUPPORT_SDR104 |
SDHCI_SUPPORT_SDR50 |
SDHCI_SUPPORT_DDR50);
+
+ /* In eMMC case vqmmc might be a fixed 1.8V regulator */
+ if (!regulator_is_supported_voltage(mmc->supply.vqmmc, 2700000,
+ 3600000))
+ host->flags &= ~SDHCI_SIGNALING_330;
+
if (ret) {
pr_warn("%s: Failed to enable vqmmc regulator: %d\n",
mmc_hostname(mmc), ret);