summaryrefslogtreecommitdiff
diff options
context:
space:
mode:
authorMing Lu <ming.lu@citrix.com>2019-01-24 13:25:42 +0800
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>2019-03-23 08:44:26 +0100
commit930cc2bd8d5c85cbf5b3e53905dd7037ee5064aa (patch)
tree46809d004ae45109cb6831285039d23ab7148f52
parente7e01b2acf94916f190a705c11e0e1d0b3d07c1c (diff)
scsi: libfc: free skb when receiving invalid flogi resp
[ Upstream commit 5d8fc4a9f0eec20b6c07895022a6bea3fb6dfb38 ] The issue to be fixed in this commit is when libfc found it received a invalid FLOGI response from FC switch, it would return without freeing the fc frame, which is just the skb data. This would cause memory leak if FC switch keeps sending invalid FLOGI responses. This fix is just to make it execute `fc_frame_free(fp)` before returning from function `fc_lport_flogi_resp`. Signed-off-by: Ming Lu <ming.lu@citrix.com> Reviewed-by: Hannes Reinecke <hare@suse.com> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com> Signed-off-by: Sasha Levin <sashal@kernel.org>
-rw-r--r--drivers/scsi/libfc/fc_lport.c6
1 files changed, 3 insertions, 3 deletions
diff --git a/drivers/scsi/libfc/fc_lport.c b/drivers/scsi/libfc/fc_lport.c
index e01a29863c38..867fc036d6ef 100644
--- a/drivers/scsi/libfc/fc_lport.c
+++ b/drivers/scsi/libfc/fc_lport.c
@@ -1739,14 +1739,14 @@ void fc_lport_flogi_resp(struct fc_seq *sp, struct fc_frame *fp,
fc_frame_payload_op(fp) != ELS_LS_ACC) {
FC_LPORT_DBG(lport, "FLOGI not accepted or bad response\n");
fc_lport_error(lport, fp);
- goto err;
+ goto out;
}
flp = fc_frame_payload_get(fp, sizeof(*flp));
if (!flp) {
FC_LPORT_DBG(lport, "FLOGI bad response\n");
fc_lport_error(lport, fp);
- goto err;
+ goto out;
}
mfs = ntohs(flp->fl_csp.sp_bb_data) &
@@ -1756,7 +1756,7 @@ void fc_lport_flogi_resp(struct fc_seq *sp, struct fc_frame *fp,
FC_LPORT_DBG(lport, "FLOGI bad mfs:%hu response, "
"lport->mfs:%hu\n", mfs, lport->mfs);
fc_lport_error(lport, fp);
- goto err;
+ goto out;
}
if (mfs <= lport->mfs) {