diff options
author | Marcel Ziswiler <marcel.ziswiler@toradex.com> | 2019-12-18 22:52:20 +0100 |
---|---|---|
committer | Marcel Ziswiler <marcel.ziswiler@toradex.com> | 2019-12-18 22:52:20 +0100 |
commit | 1ddf624b0b268fdc0b80b1de618b98f8d117afea (patch) | |
tree | 3d3218332bcb34cb0afa01d6ad996058a3dbcb77 /drivers/platform/x86/pmc_atom.c | |
parent | 6b774eec1f9d3064e9b33634dfa99d5666d0a73a (diff) | |
parent | bfb9e5c03076a446b1f4f6a523ddc8d723c907a6 (diff) |
Merge tag 'v4.14.159' into 4.14-2.0.x-imx
This is the 4.14.159 stable release
Conflicts:
arch/arm/Kconfig.debug
arch/arm/boot/dts/imx7s.dtsi
arch/arm/mach-imx/cpuidle-imx6sx.c
drivers/crypto/caam/caamalg.c
drivers/crypto/mxs-dcp.c
drivers/dma/imx-sdma.c
drivers/input/keyboard/imx_keypad.c
drivers/net/can/flexcan.c
drivers/net/can/rx-offload.c
drivers/net/wireless/ath/ath10k/pci.c
drivers/pci/dwc/pci-imx6.c
drivers/spi/spi-fsl-lpspi.c
drivers/usb/dwc3/gadget.c
Diffstat (limited to 'drivers/platform/x86/pmc_atom.c')
-rw-r--r-- | drivers/platform/x86/pmc_atom.c | 48 |
1 files changed, 48 insertions, 0 deletions
diff --git a/drivers/platform/x86/pmc_atom.c b/drivers/platform/x86/pmc_atom.c index 50f2a125cd2c..971ae892c611 100644 --- a/drivers/platform/x86/pmc_atom.c +++ b/drivers/platform/x86/pmc_atom.c @@ -428,12 +428,60 @@ static int pmc_dbgfs_register(struct pmc_dev *pmc) */ static const struct dmi_system_id critclk_systems[] = { { + /* pmc_plt_clk0 is used for an external HSIC USB HUB */ .ident = "MPL CEC1x", .matches = { DMI_MATCH(DMI_SYS_VENDOR, "MPL AG"), DMI_MATCH(DMI_PRODUCT_NAME, "CEC10 Family"), }, }, + { + /* pmc_plt_clk0 - 3 are used for the 4 ethernet controllers */ + .ident = "Lex 3I380D", + .matches = { + DMI_MATCH(DMI_SYS_VENDOR, "Lex BayTrail"), + DMI_MATCH(DMI_PRODUCT_NAME, "3I380D"), + }, + }, + { + /* pmc_plt_clk* - are used for ethernet controllers */ + .ident = "Beckhoff CB3163", + .matches = { + DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"), + DMI_MATCH(DMI_BOARD_NAME, "CB3163"), + }, + }, + { + /* pmc_plt_clk* - are used for ethernet controllers */ + .ident = "Beckhoff CB4063", + .matches = { + DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"), + DMI_MATCH(DMI_BOARD_NAME, "CB4063"), + }, + }, + { + /* pmc_plt_clk* - are used for ethernet controllers */ + .ident = "Beckhoff CB6263", + .matches = { + DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"), + DMI_MATCH(DMI_BOARD_NAME, "CB6263"), + }, + }, + { + /* pmc_plt_clk* - are used for ethernet controllers */ + .ident = "Beckhoff CB6363", + .matches = { + DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"), + DMI_MATCH(DMI_BOARD_NAME, "CB6363"), + }, + }, + { + .ident = "SIMATIC IPC227E", + .matches = { + DMI_MATCH(DMI_SYS_VENDOR, "SIEMENS AG"), + DMI_MATCH(DMI_PRODUCT_VERSION, "6ES7647-8B"), + }, + }, { /*sentinel*/ } }; |