summaryrefslogtreecommitdiff
path: root/Documentation
diff options
context:
space:
mode:
Diffstat (limited to 'Documentation')
-rw-r--r--Documentation/ABI/testing/sysfs-class-bdi4
-rw-r--r--Documentation/DocBook/kernel-locking.tmpl25
-rw-r--r--Documentation/cpu-freq/governors.txt8
-rw-r--r--Documentation/hwmon/ibmaem37
4 files changed, 66 insertions, 8 deletions
diff --git a/Documentation/ABI/testing/sysfs-class-bdi b/Documentation/ABI/testing/sysfs-class-bdi
index 5ac1e01bbd48..5f500977b42f 100644
--- a/Documentation/ABI/testing/sysfs-class-bdi
+++ b/Documentation/ABI/testing/sysfs-class-bdi
@@ -14,6 +14,10 @@ MAJOR:MINOR
non-block filesystems which provide their own BDI, such as NFS
and FUSE.
+MAJOR:MINOR-fuseblk
+
+ Value of st_dev on fuseblk filesystems.
+
default
The default backing dev, used for non-block device backed
diff --git a/Documentation/DocBook/kernel-locking.tmpl b/Documentation/DocBook/kernel-locking.tmpl
index 77c42f40be5d..2510763295d0 100644
--- a/Documentation/DocBook/kernel-locking.tmpl
+++ b/Documentation/DocBook/kernel-locking.tmpl
@@ -703,6 +703,31 @@
</sect1>
</chapter>
+<chapter id="trylock-functions">
+ <title>The trylock Functions</title>
+ <para>
+ There are functions that try to acquire a lock only once and immediately
+ return a value telling about success or failure to acquire the lock.
+ They can be used if you need no access to the data protected with the lock
+ when some other thread is holding the lock. You should acquire the lock
+ later if you then need access to the data protected with the lock.
+ </para>
+
+ <para>
+ <function>spin_trylock()</function> does not spin but returns non-zero if
+ it acquires the spinlock on the first try or 0 if not. This function can
+ be used in all contexts like <function>spin_lock</function>: you must have
+ disabled the contexts that might interrupt you and acquire the spin lock.
+ </para>
+
+ <para>
+ <function>mutex_trylock()</function> does not suspend your task
+ but returns non-zero if it could lock the mutex on the first try
+ or 0 if not. This function cannot be safely used in hardware or software
+ interrupt contexts despite not sleeping.
+ </para>
+</chapter>
+
<chapter id="Examples">
<title>Common Examples</title>
<para>
diff --git a/Documentation/cpu-freq/governors.txt b/Documentation/cpu-freq/governors.txt
index 6a9c55bd556b..dcec0564d040 100644
--- a/Documentation/cpu-freq/governors.txt
+++ b/Documentation/cpu-freq/governors.txt
@@ -129,14 +129,6 @@ to its default value of '80' it means that between the checking
intervals the CPU needs to be on average more than 80% in use to then
decide that the CPU frequency needs to be increased.
-sampling_down_factor: this parameter controls the rate that the CPU
-makes a decision on when to decrease the frequency. When set to its
-default value of '5' it means that at 1/5 the sampling_rate the kernel
-makes a decision to lower the frequency. Five "lower rate" decisions
-have to be made in a row before the CPU frequency is actually lower.
-If set to '1' then the frequency decreases as quickly as it increases,
-if set to '2' it decreases at half the rate of the increase.
-
ignore_nice_load: this parameter takes a value of '0' or '1'. When
set to '0' (its default), all processes are counted towards the
'cpu utilisation' value. When set to '1', the processes that are
diff --git a/Documentation/hwmon/ibmaem b/Documentation/hwmon/ibmaem
new file mode 100644
index 000000000000..2fefaf582a43
--- /dev/null
+++ b/Documentation/hwmon/ibmaem
@@ -0,0 +1,37 @@
+Kernel driver ibmaem
+======================
+
+Supported systems:
+ * Any recent IBM System X server with Active Energy Manager support.
+ This includes the x3350, x3550, x3650, x3655, x3755, x3850 M2,
+ x3950 M2, and certain HS2x/LS2x/QS2x blades. The IPMI host interface
+ driver ("ipmi-si") needs to be loaded for this driver to do anything.
+ Prefix: 'ibmaem'
+ Datasheet: Not available
+
+Author: Darrick J. Wong
+
+Description
+-----------
+
+This driver implements sensor reading support for the energy and power
+meters available on various IBM System X hardware through the BMC. All
+sensor banks will be exported as platform devices; this driver can talk
+to both v1 and v2 interfaces. This driver is completely separate from the
+older ibmpex driver.
+
+The v1 AEM interface has a simple set of features to monitor energy use.
+There is a register that displays an estimate of raw energy consumption
+since the last BMC reset, and a power sensor that returns average power
+use over a configurable interval.
+
+The v2 AEM interface is a bit more sophisticated, being able to present
+a wider range of energy and power use registers, the power cap as
+set by the AEM software, and temperature sensors.
+
+Special Features
+----------------
+
+The "power_cap" value displays the current system power cap, as set by
+the Active Energy Manager software. Setting the power cap from the host
+is not currently supported.