From cbc41d0a761bffb3166a413a3c77100a737c0cd7 Mon Sep 17 00:00:00 2001 From: Geert Uytterhoeven Date: Tue, 4 Aug 2015 14:28:15 +0200 Subject: drivers: sh: Disable PM runtime for multi-platform ARM with genpd If the default PM Domain using PM_CLK is used for PM runtime, the real Clock Domain cannot be registered from DT later. Hence do not enable it when running a multi-platform kernel with genpd support on R-Car or RZ. The CPG/MSTP Clock Domain driver will take care of PM runtime management of the module clocks. Now most multi-platform ARM shmobile platforms (SH-Mobile, R-Mobile, R-Car, RZ) use DT-based PM Domains to take care of PM runtime management of the module clocks, simplify the platform logic by replacing the explicit SoC checks by a single check for the presence of MSTP clocks in DT. Backwards-compatiblity with old DTs (mainly for R-Car Gen2) is provided by checking for the presence of a "#power-domain-cells" property in DT. The default PM Domain is still needed for: - backwards-compatibility with old DTs that lack PM Domain properties, - the CONFIG_PM=n case, - legacy (non-DT) ARM/shmobile platforms without genpd support (r8a7778, r8a7779), - legacy SuperH. Signed-off-by: Geert Uytterhoeven Reviewed-by: Ulf Hansson Signed-off-by: Simon Horman --- drivers/sh/pm_runtime.c | 18 +++++------------- 1 file changed, 5 insertions(+), 13 deletions(-) (limited to 'drivers/sh') diff --git a/drivers/sh/pm_runtime.c b/drivers/sh/pm_runtime.c index ad9188138ed5..25abd4eb7d10 100644 --- a/drivers/sh/pm_runtime.c +++ b/drivers/sh/pm_runtime.c @@ -35,19 +35,11 @@ static struct pm_clk_notifier_block platform_bus_notifier = { static int __init sh_pm_runtime_init(void) { if (IS_ENABLED(CONFIG_ARCH_SHMOBILE_MULTI)) { - if (!of_machine_is_compatible("renesas,r7s72100") && -#ifndef CONFIG_PM_GENERIC_DOMAINS_OF - !of_machine_is_compatible("renesas,r8a73a4") && - !of_machine_is_compatible("renesas,r8a7740") && - !of_machine_is_compatible("renesas,sh73a0") && -#endif - !of_machine_is_compatible("renesas,r8a7778") && - !of_machine_is_compatible("renesas,r8a7779") && - !of_machine_is_compatible("renesas,r8a7790") && - !of_machine_is_compatible("renesas,r8a7791") && - !of_machine_is_compatible("renesas,r8a7792") && - !of_machine_is_compatible("renesas,r8a7793") && - !of_machine_is_compatible("renesas,r8a7794")) + if (!of_find_compatible_node(NULL, NULL, + "renesas,cpg-mstp-clocks")) + return 0; + if (IS_ENABLED(CONFIG_PM_GENERIC_DOMAINS_OF) && + of_find_node_with_property(NULL, "#power-domain-cells")) return 0; } -- cgit v1.2.3