summaryrefslogtreecommitdiff
path: root/drivers
diff options
context:
space:
mode:
authorStephen Warren <swarren@nvidia.com>2014-04-18 10:56:11 -0600
committerTom Warren <twarren@nvidia.com>2014-05-13 10:41:31 -0700
commitf175603f7c4fe614c913476bfec78a36ae8be7a3 (patch)
tree297ef17e72e08df2ee4692ef7ee5721606929496 /drivers
parentd2a3e911390f9fc4d8c0ee4b3c7fc75f4fd3fd19 (diff)
ARM: tegra: set CONFIG_SYS_MMC_MAX_DEVICE
If CONFIG_API is ever to be enabled on Tegra, this define must be set, since api/api_storage.c uses it. A couple of annoyting things about CONFIG_SYS_MMC_MAX_DEVICE 1) It isn't documented in README. The same is true for a lot of similar defines used by api_storage.c. 2) It doesn't represent MAX_DEVICE but rather NUM_DEVICES, since the valid values are 0..n-1 not 0..n. However, I this patch does not address those shortcomings. Signed-off-by: Stephen Warren <swarren@nvidia.com> Signed-off-by: Tom Warren <twarren@nvidia.com>
Diffstat (limited to 'drivers')
-rw-r--r--drivers/mmc/tegra_mmc.c13
1 files changed, 8 insertions, 5 deletions
diff --git a/drivers/mmc/tegra_mmc.c b/drivers/mmc/tegra_mmc.c
index ed67eec252..ca9c4aa15f 100644
--- a/drivers/mmc/tegra_mmc.c
+++ b/drivers/mmc/tegra_mmc.c
@@ -18,7 +18,7 @@
DECLARE_GLOBAL_DATA_PTR;
-struct mmc_host mmc_host[MAX_HOSTS];
+struct mmc_host mmc_host[CONFIG_SYS_MMC_MAX_DEVICE];
#ifndef CONFIG_OF_CONTROL
#error "Please enable device tree support to use this driver"
@@ -669,13 +669,14 @@ static int process_nodes(const void *blob, int node_list[], int count)
void tegra_mmc_init(void)
{
- int node_list[MAX_HOSTS], count;
+ int node_list[CONFIG_SYS_MMC_MAX_DEVICE], count;
const void *blob = gd->fdt_blob;
debug("%s entry\n", __func__);
/* See if any Tegra124 MMC controllers are present */
count = fdtdec_find_aliases_for_id(blob, "sdhci",
- COMPAT_NVIDIA_TEGRA124_SDMMC, node_list, MAX_HOSTS);
+ COMPAT_NVIDIA_TEGRA124_SDMMC, node_list,
+ CONFIG_SYS_MMC_MAX_DEVICE);
debug("%s: count of Tegra124 sdhci nodes is %d\n", __func__, count);
if (process_nodes(blob, node_list, count)) {
printf("%s: Error processing T30 mmc node(s)!\n", __func__);
@@ -684,7 +685,8 @@ void tegra_mmc_init(void)
/* See if any Tegra30 MMC controllers are present */
count = fdtdec_find_aliases_for_id(blob, "sdhci",
- COMPAT_NVIDIA_TEGRA30_SDMMC, node_list, MAX_HOSTS);
+ COMPAT_NVIDIA_TEGRA30_SDMMC, node_list,
+ CONFIG_SYS_MMC_MAX_DEVICE);
debug("%s: count of T30 sdhci nodes is %d\n", __func__, count);
if (process_nodes(blob, node_list, count)) {
printf("%s: Error processing T30 mmc node(s)!\n", __func__);
@@ -693,7 +695,8 @@ void tegra_mmc_init(void)
/* Now look for any Tegra20 MMC controllers */
count = fdtdec_find_aliases_for_id(blob, "sdhci",
- COMPAT_NVIDIA_TEGRA20_SDMMC, node_list, MAX_HOSTS);
+ COMPAT_NVIDIA_TEGRA20_SDMMC, node_list,
+ CONFIG_SYS_MMC_MAX_DEVICE);
debug("%s: count of T20 sdhci nodes is %d\n", __func__, count);
if (process_nodes(blob, node_list, count)) {
printf("%s: Error processing T20 mmc node(s)!\n", __func__);